A five-day wind lull pushed the grid to about 252 g/kWh. SAP 10.3 assumes 86.

From 6 to 10 November 2026, wind fell to between 2% and 10% of Britain's electricity and gas supplied more than 60% on three of those days. Grid carbon intensity stayed above 220 gCO₂/kWh for five days running. Here is what that means for the electricity factor in your SAP and HEM calculations, and what it doesn't mean.

GridMonkey — free in your browser

See what the grid is actually running on right now

The live generation mix, the carbon intensity readout, the 24-hour trend and the breakdown by generator — the real-world context behind the electricity factor SAP applies.

Completely free. No sign-up, no ads, no catch.

Quick answer: For five days from 6 to 10 November 2026, wind supplied only 2–10% of Britain’s electricity and gas supplied 55–61%. NESO’s Carbon Intensity API shows daily average grid carbon intensity of 238–261 gCO₂/kWh across those days, peaking at 279 g on 9 November. That is roughly three times the 0.086 kgCO₂e/kWh (86 g) that SAP 10.3 uses for grid electricity, and almost double SAP 10.2’s 0.136. Two days later, on 12 November, the wind returned and the daily average fell to 118 g. None of this changes how a dwelling is assessed: SAP and HEM use fixed, published factors. But it shows how much an annual factor smooths over, and it is the context worth having when a client asks whether a heat pump is “really” low-carbon in a cold, still week.

What happened

The lull started on Friday 6 November. Analyst Kathryn Porter’s Watt-Logic write-up reported that wind was forecast to fall as low as about 500 MW that day, against an installed base of roughly 34 GW. The calm was forecast to last four days. It went on longer than that.

NESO’s generation-mix data for the period (6–10 November) shows how far the system fell back on gas:

Day (UTC)WindGasNuclearImportsBiomassAverage intensityPeak intensity
Fri 6 Nov8.8%55.2%14.1%6.2%9.0%238 g256 g
Sat 7 Nov3.5%60.5%15.1%5.6%9.1%256 g272 g
Sun 8 Nov2.2%61.4%15.3%6.1%8.9%260 g277 g
Mon 9 Nov3.4%60.5%13.6%5.9%8.5%261 g279 g
Tue 10 Nov10.4%57.4%13.3%4.1%8.4%245 g267 g

Generation shares are unweighted averages of NESO’s half-hourly percentages. Intensity figures are NESO’s “actual” half-hourly estimates in gCO₂/kWh.

Across the five days from 6 to 10 November, intensity averaged about 252 g/kWh and never fell below 220 g.

It was also expensive. The same Watt-Logic analysis, which draws on NESO’s published interconnector auction data, found NESO paying up to about £2,540/MWh for extra imports on 6 November. It also accepted offers from gas plants at close to £1,000/MWh in the Balancing Mechanism.

The contrast at either end of the lull is stark. On 2 November the daily average was 147 g. On 12 November it was 118 g, and in the early hours of 13 November it touched 85 g, close to SAP 10.3’s annual figure, for a single half-hour.

Why the SAP factor looks so different

SAP and HEM electricity factors aren’t snapshots of the grid on a given day. They are projected averages, chosen so that a dwelling’s emissions rate reflects the grid over the period the home will actually run.

SAP 10.3, the methodology for the Future Homes Standard, cuts the grid electricity carbon factor from 0.136 to 0.086 kgCO₂e/kWh. That reflects the expected decarbonisation of the grid over the coming years. It is a deliberate forward-looking assumption, and a calm November week in 2026 doesn’t contradict it. Over the first fortnight of November as a whole, intensity averaged about 193 g/kWh. Over a full year, with summer solar and windy months included, the real-world figure is much lower than in a winter lull.

What the November figures do show is variation. A heat pump’s electricity demand is highest in exactly the cold, still, high-pressure weather that produces lulls like this one. A single annual factor, however good, can’t show that.

What it means in practice

For compliance, nothing changes. Your DER and TER, and your DPER and TPER, are calculated with the fixed factors in the approved methodology: SAP 10.2 for Part L 2021 work, SAP 10.3 for schemes under the Future Homes Standard. You don’t adjust them for the weather, and Building Control won’t expect you to.

For conversations with clients, the numbers are useful.

See the grid for yourself

Our live grid mix shows Britain’s generation mix and carbon intensity as they happen, with the 24-hour trend and a breakdown by generator. It is the real-world context behind the number SAP applies. If you’re preparing a client explainer or an energy statement and want to show where the factor comes from, it’s a good place to start.

Sources: NESO Carbon Intensity API: intensity, 1–15 November 2026 · NESO Carbon Intensity API: generation mix, 6–9 November 2026 and 10 November 2026 · Watt-Logic: “Was NESO panic buying spare capacity on 6 November 2026?” · NESO interconnector auction data

Got a project this affects?

GridMonkey is free in your browser, so you can see where your own scheme lands before anyone else asks. Want it done for you instead? Send the drawings over.