This dwelling type —
— l/p/d vs 125 —

Project details cover page

Dwelling types

💡 Save money by bundling: one report covers any number of identical plots for one fee — group dwellings that share the same sanitaryware into a single type and list the plots it covers. Extra types in the same report are only £15 +VAT each.

Quick presets

Presets fill the selected dwelling type with realistic starting values — then tweak to match the actual specification.

Dwelling type

First time here? Nearly all of the answer comes from Table 1 below — the fittings. Every row has an i telling you which figure off the spec sheet to use.
What counts as one dwelling type?

One type = one set of sanitaryware, not one plot. If plots 1–4 and 7 all have the same shower, WC, bath and taps, that is a single type covering five plots — and a single fee.

List the plots in the box so the report says which homes it applies to. Building Control needs to see the coverage, and it is also what stops you paying for the same calculation five times.

The target is 125 l/p/d unless a planning condition imposed the optional 110. Check the decision notice — this is the single most common thing to get wrong on an otherwise correct calculation.

125 l/p/d is the standard requirement (Building Regulation 36 / AD G). 110 l/p/d applies where the optional requirement is imposed as a planning condition — check the decision notice.

Table 1 — fittings

litres/person/day = (1)×(2)+(3)
Installation typeEntryCapacity / flow (1)Use factor (2)Fixed (3)l/p/d (4)
Where does every one of these numbers come from?

All of it is manufacturer product data, off the spec sheets your sanitaryware schedule already cites. You only ever fill the Capacity / flow column — the use factors and fixed allowances are set by the DCLG methodology and cannot be changed.

  • WCs — flush volume(s) in litres; a dual flush is quoted like "6/4 litre".
  • Taps and showers — litres/minute at 3 bar (0.1–0.5 bar for gravity). If a flow regulator is fitted, use the regulator’s rating. Bath taps are excluded.
  • Baths — capacity to the overflow, not the brim, off the technical drawing.
  • Appliances — from the energy label: water per cycle ÷ load in kg, or ÷ place settings. Leave the defaults if the appliance is not chosen yet.

Several different specs of the same fitting? Use the multiple-fittings button on that row: the official rule takes the greater of the average and 70% of the highest, so one ultra-low fitting cannot drag the average down.

Over target? The shower is almost always the biggest single item, with the WC second. The result panel names the one change that would fix it.

(5) Total calculated use —

Greywater recycling

Rainwater harvesting

Totals — Regulation 36 / AD G

What are rows 5 to 11 doing?

This is Regulation 36 set out line by line, and none of it is editable — it is arithmetic on the fittings above.

  • (5) total calculated use from Table 1.
  • (6) (7) less any greywater and rainwater contribution.
  • (8) the normalisation factor, × 0.91.
  • (10) external water use, a flat + 5.0 l/p/d.
  • (11) the total that must meet your target.

The verdict is judged on the unrounded row 11, so a spec displaying exactly 125.0 can still fail on the true decimal. Leave yourself a little headroom — installed spec has a way of drifting from what was drawn.

Result — selected type

—
litres/person/day vs 125 target

Defra has proposed cutting the Part G standard from 125 to 105 l/p/d (and the optional standard from 110 to 100), intended during 2026 with a six-month transition. Proposal only — not in force: today's standards remain 125 and 110.

Where the water goes

Project summary

Branded 2-page report for Building Control submission.
£25 +VAT first dwelling type · £15 +VAT each additional type (£30 / £18 inc VAT).
See an example report

1 dwelling type(s) Report fee: £25 +VAT More free tools →