1 Project details

What does the work include?
Applies to dwellings in England under Approved Document L Volume 1 (2021 edition incorporating 2023 amendments). The 2026 edition takes effect for work starting on or after 24 March 2027.

Result

Free to use on screen. See an example report

Report logo: Energycount — consultants: brand the report as your own

2 The extension

All storeys of the extension added together
Only affects the default floor and roof areas
Windows, doors, roof windows and rooflights in the extension
DescriptionTypeW (m)H (m)QtyAreaU (W/m²K)
Table 4.2 limits: windows, doors and in-plane roof windows 1.4 W/m²K (or WER band B / DSER band B–C); rooflights on an upstand 2.2 W/m²K. Use the manufacturer's whole-unit U-value, not the centre-pane figure. For an odd shape enter the area as the width with a height of 1.
Existing windows and doors the extension covers over added to the allowance
DescriptionArea each (m²)QtyArea
Only openings that no longer exist or are no longer exposed because of the extension count (para 10.10) — a back door that now opens into the extension, a window bricked up to build it.
Walls, roof and floor of the extension net areas, heat-loss elements only
Exclude the wall shared with the house
Limit 0.18 · exact value in U-Monkey
Measured on the slope for a pitched roof
Limit 0.15
The heat-loss floor — normally the footprint
Limit 0.18
Assessor options

Area-weighted U-value — proposed extension vs notional extension

ElementProposed A (m²)Proposed UU·A (W/K)Notional A (m²)Notional UU·A (W/K)

About this tool & the method

Approved Document L Volume 1 (2021) limits the windows, doors and rooflights of an extension to 25 % of its floor area plus any openings it covers over (para 10.10), and every new element must meet the Table 4.2 U-values. Go over the allowance and you have two routes: show that the area-weighted U-value of the whole extension is no worse than a notional extension of the same size and shape built to Table 4.2 with 25 % openings, or commission a whole-dwelling SAP calculation. GlazeMonkey runs the first two checks and the area-weighted comparison live, tests a conservatory or porch against the five exemption conditions, and checks renovated, replaced and retained elements against the Table 4.3 thresholds and the 15-year payback rule. The notional extension keeps the proposed openings in proportion up to the allowance and returns the excess to wall (0.18) or roof (0.15) at their limiting values. Method and figures: ADL1 2021 incorporating 2023 amendments, Sections 4, 10 and 11 and Appendix C. Not a substitute for a Building Control body's judgement.

Energycount Limited · GlazeMonkey · Approved Document L Volume 1 (England), 2021 edition incorporating 2023 amendments · Not a substitute for site-specific professional judgement